id: SUS01
pillar: sustainability
title: SUS 1. How do you measure the resource consumption of your workload?
description: Cost has an invoice and latency has a timer. Consumption has proxies, which makes this the only pillar whose first question is whether measurement works at all.
status: draft
services: []
sidebar:
  order: 10
  label: Measurement
source_url: "https://framework.stackit.cloud/architecture/pillars/sustainability/sus-01-measurement/"
source_file: "docs/architecture/pillars/sustainability/sus-01-measurement.mdx"
---

Every pillar begins with measurement. This one begins with whether measurement is possible, which
is a different and less comfortable question.

Cost is on an invoice. Latency is on a timer. Environmental footprint depends on facts that are
not visible from inside a virtual machine: how the hardware is shared, how the facility is
powered, and what the marginal energy source was at the moment your job ran. What you can observe
are proxies, and the honest starting point is knowing which ones you have and what each of them
omits.

## Best practices

- [`SUS 1.1`](/architecture/pillars/sustainability/sus-01-measurement/#sus-11-establish-what-you-can-actually-measure-before-setting-a-target-against-it) Establish what you can actually measure before setting a target against it
- [`SUS 1.2`](/architecture/pillars/sustainability/sus-01-measurement/#sus-12-use-proxies-you-can-defend-and-state-what-each-one-omits) Use proxies you can defend, and state what each one omits
- [`SUS 1.3`](/architecture/pillars/sustainability/sus-01-measurement/#sus-13-separate-what-the-provider-controls-from-what-you-control) Separate what the provider controls from what you control
- [`SUS 1.4`](/architecture/pillars/sustainability/sus-01-measurement/#sus-14-do-not-optimize-a-metric-that-does-not-track-physical-consumption) Do not optimize a metric that does not track physical consumption

---

## SUS 1.1 Establish what you can actually measure before setting a target against it

**Risk if not established:** Medium

A target set against a metric nobody can produce is a reporting exercise waiting to happen. Start
from the signals that exist rather than from the figure you would like to report.

The order matters. Establish the available measurements, decide which of them correlate with
consumption, then set targets against those. Reversing it produces a target that gets satisfied by
changing how it is calculated.

Distinguish three kinds of figure, because they have very different reliability. **Directly
measured** quantities such as allocated capacity, storage volume and running hours. **Derived**
quantities such as an emissions estimate produced from those by applying factors. And **provider
figures** such as facility efficiency, which describe the infrastructure rather than your
workload.

Only the first is yours to verify. The other two depend on methodology you did not choose and may
not be able to inspect, which is worth knowing before a number ends up in a report with your name
on it.

**On STACKIT.** Two provider-level facts are published and both are relevant, because they set the
context your workload sits in. All data centres are operated on green electricity from regional
sources in Germany and Austria, and the facility in Ostermiething reports a <LinkChip href="https://stackit.com/en/learn/knowledge/cloud/sustainability">PUE of
1.1</LinkChip>, which is a strong figure by
European standards.

The same page states that integrated tools let companies measure the energy consumption and
emissions of their cloud services. That capability would change this question substantially, and
it is the single most consequential thing to confirm before designing a measurement approach.

Establish four things about that reporting before an obligation rests on it: where it is
available, what it reports, at what granularity, and by what methodology. A figure whose
methodology you cannot state is not evidence for a disclosure. Until those four are answered, the
proxies in [`SUS 1.2`](/architecture/pillars/sustainability/sus-01-measurement/#sus-12-use-proxies-you-can-defend-and-state-what-each-one-omits) are what a measurement approach should stand on.

**Tradeoffs.** **Operational Excellence.** Time spent establishing what is measurable before
measuring anything, which feels like delay and prevents building on a figure that turns out not to
exist.

**Verify.** Which consumption figures can you produce for your workload today? For each, where
does it come from and who calculated it?

---

## SUS 1.2 Use proxies you can defend, and state what each one omits

**Risk if not established:** Medium

Where direct measurement is unavailable, proxies are the working answer. They are legitimate
provided their limits are stated, and misleading when presented as measurements.

The proxies that correlate reasonably with consumption and that you can produce yourself:

- **Allocated capacity**, meaning vCPU, memory and storage provisioned rather than used. It
  correlates with hardware occupied, which is the physical quantity.
- **The gap between allocated and used**, which is the waste this pillar addresses and the figure
  most likely to produce action.
- **Running hours**, particularly for resources that could be off, which is [`SUS 6`](/architecture/pillars/sustainability/sus-06-shut-down-idle/).
- **Stored volume and its growth rate**, which correlates with hardware occupied over time.

Each omits something. Allocated capacity says nothing about the efficiency of the hardware or the
facility. Running hours treat an idle instance and a saturated one identically. None of them
capture embodied footprint, which was paid at manufacture regardless of use.

State the omissions where the figure is used. A proxy with its limits attached is an honest input
to a decision; the same proxy presented as a measurement is a claim you cannot support.

**On STACKIT.** These proxies come from the same sources the other pillars already use:
utilization from
<LinkChip href="https://docs.stackit.cloud/products/logging-and-monitoring/observability/">Observability</LinkChip>,
storage volume and growth from the services holding it, and allocated capacity from the resource
inventory.

Cost is the most available proxy and the most misleading one, which is why it has its own best
practice in [`SUS 1.4`](/architecture/pillars/sustainability/sus-01-measurement/#sus-14-do-not-optimize-a-metric-that-does-not-track-physical-consumption). The
<LinkChip href="https://docs.stackit.cloud/platform/cost-and-billing/cost-dashboard/">Cost Dashboard</LinkChip> makes it
easy to reach for, and its per-project breakdown is genuinely useful for locating waste even where
it is a poor proxy for consumption.

**Tradeoffs.** **Operational Excellence.** Maintaining proxy measurements is work with no external
reporting value until the direct figures exist, which makes it easy to defer.

**Verify.** For each consumption figure you report, is it measured, derived or a proxy? Where is
the limitation of each stated?

---

## SUS 1.3 Separate what the provider controls from what you control

**Risk if not established:** Medium

Sustainability figures mix two very different things: how efficiently the infrastructure runs, and
how much of it you use. Conflating them produces a number nobody can act on, because half of it is
not yours.

The provider layer covers energy sourcing, facility efficiency, cooling, and hardware lifecycle.
Those are procurement decisions rather than architecture decisions, and they belong in the choice
of provider rather than in a design review.

Your layer is the amount of infrastructure you occupy and for how long. That is what every other
question in this pillar addresses, and it is the only part a workload design can change.

Keeping them separate has a practical benefit beyond clarity: it prevents the argument that
efficiency at the provider layer removes the need for efficiency at yours. Green electricity makes
consumption cleaner and does not make it free, and it certainly does not make idle capacity
justified.

**On STACKIT.** The provider layer is documented and strong: green electricity from regional
sources across all data centres, and a <LinkChip href="https://stackit.com/en/learn/knowledge/cloud/sustainability">PUE of 1.1 in
Ostermiething</LinkChip> achieved with river
water cooling and heat recovery.

That is worth knowing precisely because it tells you where your remaining lever is. When the
infrastructure layer is already efficient, the variable that is left is how much of it you occupy,
which is why this pillar's centre of gravity is [`SUS 4`](/architecture/pillars/sustainability/sus-04-utilization-density/) rather than anything the platform
provides.

**Tradeoffs.** None. This is a framing decision that costs nothing and prevents a category of
unproductive argument.

**Verify.** In your sustainability reporting, which figures describe the provider's infrastructure
and which describe your workload? Can a reader tell them apart?

---

## SUS 1.4 Do not optimize a metric that does not track physical consumption

**Risk if not established:** Medium

This is the failure mode the whole question exists to prevent. A workload optimized against a
number that does not correspond to physical reality has achieved a reporting outcome, and
distinguishing that from an environmental one is most of the discipline in this pillar.

Cost is the metric this happens with most often, because it is available, precise and looks
authoritative. It diverges from consumption in specific and predictable ways, which the
[Sustainability tradeoffs](/architecture/pillars/sustainability/tradeoffs/) set out: committed capacity is cheaper and equally
allocated, cheaper storage tiers remove the pressure to delete without freeing any hardware, and
cost optimization stops when spend is acceptable while consumption keeps mattering.

Test any metric before optimizing against it by asking what would happen if you improved it
without changing anything physical. If that is possible, the metric is measuring an accounting
artefact.

Where cost and consumption agree, use cost. It is easier to obtain, easier to fund and reaches
decision-makers. Where they diverge, this pillar needs its own argument, and having named the
divergence in advance is what makes that argument possible.

**On STACKIT.** The clearest divergence available on the platform is the shelving distinction from
[`COST 5.2`](/architecture/pillars/cost-optimization/cost-05-environments/#cost-52-shut-down-what-is-not-being-used-and-know-what-stopping-actually-stops), and it runs in the direction that favours sustainability. A machine that is stopped
without shelving keeps its resource reservation, which means it is still occupying capacity as
well as still being billed. Shelving releases both.

That makes it one of the few places where the cost signal and the physical signal point the same
way, which is worth using rather than arguing about.

**Tradeoffs.** **Cost Optimization**, occasionally. Where the two diverge, following consumption
rather than cost means spending money for an outcome that does not appear on the invoice.

**Verify.** Take your main sustainability metric. Could it improve without any change to how much
hardware you occupy or for how long? If so, what is it actually measuring?

---

## Related

- [`SUS 2`](/architecture/pillars/sustainability/sus-02-right-sizing/) Right-sizing, the first place these measurements are applied
- [`SUS 4`](/architecture/pillars/sustainability/sus-04-utilization-density/) Utilization density, the lever the provider layer leaves to you
- [`COST 8`](/architecture/pillars/cost-optimization/cost-08-cost-visibility/) Cost visibility, whose data is the most available and most misleading proxy
- [`OPS 7`](/architecture/pillars/operational-excellence/ops-07-observability/) Observability, which supplies the utilization side
- [Sustainability tradeoffs](/architecture/pillars/sustainability/tradeoffs/), which sets out where cost and consumption part